Operational Amplifiers
RHD 5902 Quad Operational Amplifier, High Speed with Enables
- Amplifier channels
- 4
- Enable grouping
- Two amplifier pairs
- Package
- 16-pin hermetic ceramic SOIC
Specifications
| Part Number | 5902-901-2S |
|---|---|
| Flight Grade | DLA RHA Certified |
| Supply Voltage | +5.0V |
| Input Offset Voltage | -4 to 4 mV |
| PSSR | 70 dB |
| CMRR | 60 dB |
| Sel Immune | >100 MeV·cm²/mg |
| Package | 16-pin, Hermetic ceramic SOIC Solder Dipped .417"L x .300"W x .120"Ht |
Technical specifications
| Specification | Value | Notes |
|---|---|---|
| Amplifier channels | 4 | |
| Recommended supply voltage | 3.3 V to 5.0 V | Electrical-performance limits are specified at +5.0 V unless otherwise stated; do not infer equivalent characterization at every supply setting. |
| Unity-gain bandwidth | 35 MHz typical | Page 4 identifies RL = 10 kΩ for the typical bandwidth; this is not a guaranteed minimum. |
| Enable grouping | Two amplifier pairs | |
| Package | 16-pin hermetic ceramic SOIC | |
| Ordered radiation assurance | 1 Mrad(Si) | Exact RHA ordering option only. Family irradiation dose rate: 50–300 rad(Si)/s; electrical and post-radiation test conditions remain per datasheet. Irradiation bias and electrical-test supply conditions must follow the datasheet; no assurance at an uncharacterized voltage is implied. |
Values are subject to the conditions and ordering options in the referenced product documentation.
Product overview
The RHD5902 integrates four operational amplifiers with enable controls for two amplifier pairs. Disabling a pair places its outputs in a high-impedance state and powers down those amplifiers. The device supports rail-to-rail input and output operation, with unity-gain stability under the normal conditions described in the datasheet. Diodes protect the input and output pins. The CMOS output stages tolerate momentary shorts, although the device does not provide on-chip thermal shutdown. Single-supply and dual-supply arrangements are described in the application examples. Electrical limits, output loading and radiation assurance must follow the selected ordering option and stated test conditions.
Documentation
Technical documents and resources
For product questions or additional technical information, contact Frontgrade https://www.frontgrade.com/contact-us-form.
More about this product
Product features
- Pairwise amplifier enable/disable
- High-impedance outputs when disabled
- Rail-to-rail inputs and outputs
- Diode-protected inputs and outputs
Control shared analog outputs
Use the pairwise enables to disconnect inactive amplifiers from a shared signal path. Evaluate the loading and settling behavior using the datasheet operating and switching conditions.
Applications
- Analog signal conditioning
Discuss your application
Contact Frontgrade to discuss RHD 5902 Quad Operational Amplifier, High Speed with Enables and the requirements of your application.